To access the boot change fields, stop the gateway from booting by pressing any key when prompted to do so.
At the command prompt, type p to display the current table (only required information is shown), or type c to go through the table line by line in edit mode.
SX-200 NSU:
boot device : flash0 <-----If something else is seen, only type 'flash'. The NSU adds the zero.
processor number : 0
host name :
file name : vxworks
inet on ethernet (e) : 192.168.60.113:ffffff00 <------ Use your IP address here
inet on backplane (b):
host inet (h) :
gateway inet (g) :
user (u) :
ftp password (pw) (blank = use rsh):
flags (f) : 0x0
target name (tn) :
startup script (s) :
other (o) : flash,c:/,xqt,b_loader.cmd
SX-200 PRI Card:
boot device : flash0 <-----If something else is seen, only type 'flash'. The PRICard adds the zero.
processor number : 0
host name :
file name : vxworks
inet on ethernet (e) : 192.168.60.114:ffffff00 <------ Use your IP address here
inet on backplane (b):
host inet (h) :
gateway inet (g) : 192.168.60.1
user (u) :
ftp password (pw) (blank = use rsh):
flags (f) : 0x0
target name (tn) :
startup script (s) :
other (o) : flash,c:\,xqt,sx2c-na.cmd
If any error is made while entering information, the delete/backspace key(s) will not work correctly leaving unseen characters in the string that will not allow the gateway to boot.
You must hit enter repeatedly until the command prompt is seen again or press ^d, then c to re-edit the table.
When complete, type @ at the command prompt to reboot the gateway. The gateway will not come up unless connected to a properly configured bay position on the SX-200. |