Knowledge Base Article
Back
Article ID #
05-3849-00988
Article Type
Troubleshooting Guide
Article Title
Name and number display support on PRI trunks
Publish Date
Feb-23-2005
Description/Symptoms
Outbound name is only supported by PRI trunks that use DMS-100 or QSIG protocols.
Body/Solutions
The following chart details Name support for each protocol:
Protocol
Outbound
NAME Supplied by 3300 TelDir
Outbound NUMBER
Supplied by IMAT/3300
INBOUND
Name and Number
Supported
DMS-100
YES
YES
YES
DMS-250
YES
YES
YES
4ESS
NO
YES
YES
NI-2
NO
(Note1)
YES
YES
QSIG
YES
YES
YES
Euro ISDN
NO
YES
YES
Note 1
:
Some NI2 offices include the calling name but only if the CO can provide the name based
on the calling number.
Test Result
More Information
Article Search Keywords
Outbound name, Protocol, Inbound name, PRI trunks, DMS-100, DMS-250, 4ESS, NI-2, QSIG, Euro ISDN
Product(s)
Product Release(s)
3300 Integrated Communications Platform (ICP); SX-200 Integrated Communications Platform (ICP); SX-2000 Light
Various
Product Family
Operational Task
Integrated Communications Platform; PBX Telephone Systems
Troubleshooting